--- title: "Guide to Using Offline Capability of Entra ID and OIDC Fabric to secure long lived sessions" slug: "guide-using-offline-capability-of-entra-id-and-oidc-fabric-to-secure-long-lived-sessions" updated: 2025-10-02T23:20:07Z published: 2025-10-02T23:20:07Z canonical: "legacy-docs.strata.io/guide-using-offline-capability-of-entra-id-and-oidc-fabric-to-secure-long-lived-sessions" --- > ## Documentation Index > Fetch the complete documentation index at: https://legacy-docs.strata.io/llms.txt > Use this file to discover all available pages before exploring further. # Guide to Using Offline Capability of Entra ID and OIDC Fabric to secure long lived sessions ## Overview This guide demonstrates how to test long-lived sessions for proxy app type user flows using the with the new offline option in Entra ID and OIDC Identity Fabric. The test validates that user attribute changes trigger appropriate authorization decisions during active sessions, ensuring that policy rules are enforced dynamically. ## Purpose Verify that when user attributes change during an active session, the Maverics platform correctly updates headers, revokes or grants access based on updated policy evaluations, rather than relying solely on initial authentication attributes. This ensures continuous security enforcement in long-lived sessions. ## Prerequisites Before beginning this test, ensure you have: - **Maverics Orchestrator** [deployed](/v1/docs/deployments-overview-1) and running - Admin access to Entra ID or OIDC based Identity Provider with the priveledge to modify a test user properties - A test **proxy application** configured --- ## Test Procedure ### Step 1: Configure the Entra ID OIDC or Generic OIDC Identity Fabric Set up your test configuration with the following parameters: **Identity Fabric Configuration:** - Configure [**Entra ID**](/v1/docs/microsoft-entra-id-oidc-1) or an OIDC based identity provider - Enable **offline access** capability **Proxy User Flow Policy Configuration:** - Create an Access policy for a location in your proxy app. - Set the Authentication policy to use your Entra ID or OIDC fabric - Set the Authorization policy to Use rule to define access - Set rule to grants access when a specific value for an attribute will be on the Entra session. (eg. the user's first_name equals `Allan`) - Set the **policy duration lifetime to 10 seconds** (for testing purposes) - Publish your Deployment **Deploy and Test** This will a take little over an about an hour given Entra ID's minimum access token lifetime refresh interval is 1 hour. 1. Access your proxy application 2. Sign in using Entra ID credentials (using a test user) 3. Verify successful authentication and session establishment by clicking around your app ### Step 3: Modify User Attributes While the session remains active: 1. Navigate to **Entra ID** user management 2. Locate the test user and edit the properties 3. Change the attribute used in the policy decision (e.g. user's first_name) 4. Save the attribute changes 5. Note the time of modification > **Note:** This attribute change should trigger the policy rule to deny access since the first name no longer matches "Allen". ### Step 4: Wait for Token Refresh then verify Authorization Enforcement - **Wait for one hour** to allow the access token to refresh - During this period, the session will continue using the existing token After the one-hour waiting period: 1. Attempt to access the proxy application with the existing session 2. To verify that the updated user attributes have been retrieved, confirm that access is **denied** based on the policy rule 3. You can also check Orchestrator logs to verify policy evaluation occurred with updated attributes **Expected Result:** Access should be denied because the user's name no longer satisfies the policy rule. ## Important Considerations > ⚠️ **Critical Test Requirements:** > > - User attributes **must be changed while the session is still active** to properly test dynamic authorization > - The test user must have an active session before attribute modification > - Entra ID enforces a **minimum one-hour access token refresh rate** - this cannot be shortened > ⚠️ **Configuration Notes:** > > - The 10-second policy duration is for testing purposes only > - Production environments should use appropriate policy duration values based on security requirements > - Ensure offline is configured in your Entra ID or OIDC based identity fabric --- ## Reference **Video Walkthrough:** [Loom Recording - Testing Long-Lived Sessions](https://loom.com/share/f4390c3ec6e446dfba036fb99b5b45ef) [Securing Long Lived Sessions Tutorial](/v1/docs/securing-long-lived-sessions) **Related Documentation:** - [Maverics Identity Orchestration Platform](https://docs.strata.io/docs) - [OIDC Identity Fabric Configuration](https://docs.strata.io/docs/oidc-identity-fabric) --- ## Troubleshooting If the test does not produce expected results: ### Session not terminating after attribute change - Verify the policy duration has elapsed - Confirm the token refresh has occurred (check Orchestrator logs) ### Access still granted with changed attributes - Verify the policy rule syntax is correct - Check that the attribute name matches exactly in the policy - Confirm the OIDC connector is retrieving updated user info during token refresh --- ## Related Articles - [Deployments Overview](https://docs.strata.io/docs/deployments-overview) - [Extend Azure AD B2C to protect on-premises apps](https://docs.strata.io/docs/extend-azure-ad-b2c-to-protect-on-premises-apps) - [Okta (OIDC)](https://docs.strata.io/docs/okta-oidc) ---